TLC Lab Question! Why does the starting line for a TLC plate have to be 1 cm from the bottom of the plate?

We found this answers

What is the best solvent system to run crude extract on TLC? ... (starting with a ratio of 95:5, ... I have used toluene: Methanol (8:1, ... - Read more

... of the dye on the line 1 cm from the bottom of the TLC plate. ... 1. You have a polar TLC support and a nonpolar solvent to ... Why? 2. Given the TLC “picture ... - Read more

Discussion about this question


TLC Lab Question! Why does the starting line for a TLC plate have to be 1 cm from the bottom of the plate? resources

Extraction and Thin-Layer Chromatography of Chlorophyll A ...

... mark a straight line across the plate 1 cm from the ... Place the plate in the TLC jar with the pencil line right ... Answer PostLab question #3 in Lab Guide.

Thin Layer Chromatography - UCLA Chemistry and Biochemistry

The start line should be 0.5-1 cm from the bottom of the plate. ... be below the starting line of the TLC, ... on the TLC plate to have a permanent record how far ...

Home Page [www.chem.ualberta.ca]

... allow the eluent to wick up the TLC plate until it is about 1 cm from the ... when a developed TLC plate does not give ... a TLC, why should we choose ...

Thin Layer Chromatography (TLC) - Boston College

... 1 cm from the bottom along the short ... TLC plate. Line a 250 mL beaker with a piece of filter paper. ... plate that you have spotted in the beaker, ...

TLC of Amino Acids - Georgia Perimeter College

Draw a light pencil line about 1.5–2 cm from the bottom of ... above the starting line on your TLC plate! ... Q.3 Why must you use a pencil to write on the TLC ...

A Little TLC

Draw a light pencil line about 1 cm up from the bottom of the plate and all the way across it ... DIAGRAM 1: TLC plate 10. Clean lab materials. ... Research Question 1.

SHOW MORE ....

HowStuffWorks "Videos"

Plate Tectonics Videos. ... Why do men and women use separate bathrooms... 3,989 Views ... Does Consciousness Have an On/Off Switch?

Thin Layer Chromatography - Chemistry - California State ...

The value is determined by measuring the distance traveled by a substance from a starting line in the ... point about 1 cm from ... cm. Silica Gel TLC Plate. in. 100 ...

How to Calculate RF Values for Dyes | eHow

... a solvent less than 1 cm ... the starting line drawn along the bottom of the paper to the ... chromatography plate. ... How to... How Does One ...

Jiskha Homework Help - Search: TLC fluorenone2C fluorene

Why does not fluorene dissolve in 1.5M sodium ... I have a question about TLC plate ... Assume your sample spots are 1 cm above the bottom of the TLC plate.

lptlc

What is TLC and why is it ... There are two parts of a TLC plate: 1) ... Distances are typically measured in cm, from the starting line at the bottom of the plate to ...

36B-BioOrganic Modifications for Technique Experiments

Why does the acylation take place ... pencil line across the plate about 1 cm form the bottom of two TLC ... Postlab Question list. References: Lab Guide for ...

Lab flashcards | Quizlet - Simple free learning tools for ...

Why does TLC not scale-up very well ... as a single medium intensity band at 970 cm-1 ... You have performed TLC analyses in previous lab experiments and will ...

(a ) (b) - California State University, Stanislaus

Use a pencil and lightly draw a line about 1 cm above the bottom of the plate. ... Figur e 2. TLC plate (a) spotting line with f ... 1. Why might it be very difficult ...

Answers | Answers in Genesis

Don't have an account yet? Sign Up. If you already have an account, Sign in. View Cart . English/US. Offices. United States; ... Why Does Creation Matter? Apologetics

Lab TLC solvent - Docstoc.com

The TLC plate should sit on the bottom of the chamber ... is approximately 1.0 cm from the top of the TLC plate. ... Lab Questions: 1. Why are the chlorophylls ...

paper chromatography - chemguide

The diagram shows what the plate might look like ... as the solvent does; some stay much closer to the base line. ... 9.6 cm from the base line while the ...

Thin Layer Chromatography - Scribd

... (spot did not moved from starting line) and 1.0 ... A line is drawn 1 cm from the bottom of the gel ... Spotting a TLC plate does require some practice. which ...

Thin-Layer Chromatography - Prince George's Community College

... should have a flat bottom. ... A common question about TLC is which of ... hold it vertically right at the spotting line on the plate and in about 1 cm from ...

Flashcards - CHM 255 Lab final - What is the purpose in ...

... which line is connected to the top of the condenser and which line is connected to the bottom? ... TLC plate. Also, so the sample does ... Why does the ...

Thin Layer Chromatography of Analgesic tablets

... (TLC) 1. Introduction: Because ... starting from one edge of the plate. Begin at least 1.5 cm from either vertical edge ... Score a horizontal line 15 cm from the ...

Paper Chromatography - Buzzle

... it is better to use Whatman No.1 filter ... and mark a line on it at about 2-3 cm from the bottom. ... we had a question which was asking, 'Why does ethanol ...

Thin Layer Chromatographic Analyses

Which should have the larger R f value and why? 2. A TLC plate ... the spots start 1 cm from the bottom of the plate and ... Mark off four 1 cm intervals, starting ...

Lab Activity H5 Paper Chromatography of M&M’s

8.1 cm solvent front starting line ... opening and deep enough so that the paper does not touch the bottom of the ... Why was a pencil used to draw the line instead ...

RECITATION NOTES FOR EXPERIMENT # 5 A B THIN LAYER ...

Have your lab textbook available for quick reference to specific ... does not move, ... draw a horizontal line about 1 cm from the bottom of the TLC plate to mark

Experiment #4: Extraction of Spinach Pigments and Thin ...

TLC plate while non-polar ... individual components using TLC. Pre-Lab: 1. ... thin-layer plate at the mark that is at the center of the 1 cm line from the bottom ...

Experiment 6 Thin-Layer Chromatography (TLC)

starting line . 3.0 cm 8.1 cm . ... line should be parallel to the bottom edge. ... developed TLC plate must have looked like.

Jiskha Homework Help - Search: Tlc

I have a question about TLC plate ... Ochem Lab why is it important to spot samples ... Assume your sample spots are 1 cm above the bottom of the TLC plate.

Organic Chem Lab- Quiz Questions and Answers.doc

... that the initial spot on a TLC plate does not streak ... about 3200 cm-1. ... have at least one a-carbon Why does water leave so easily from the ...

Thin layer chromatography TLC - Department of Chemistry ...

Development consists of placing the bottom of the TLC plate into ... line about 1 cm from the end of a plate ... Why must the spot be applied to the TLC plate above ...

THIN LAYER CHROMATOGRAPHY- TLC - Georgia Perimeter College

The unknown mixtures for this lab will have at least two ... be closest to the base line of the developed TLC plate ... the top of the plate (about 1.5 cm from ...

Thin Layer Chromatography (TLC) Guide - MIT OpenCourseWare ...

Steps for TLC: 1) Cut TLC plates. ... but does not put anything on the solvent front ... Spot the compound on the baseline of the TLC plate. We will use commercial